Piezosurgery in endoscopic dacryocystorhinostomy
2009
Piezosurgery is a recently developed system for cutting bone with microvibrations. The equipment consists of two hand pieces, two inserts, and two peristaltic pumps connected to the control unit. The device is endowed with an irrigation system of high-flow saline solution that breaks up into very small particles, with a “bloodless” effect on the surgical site and a low indirect thermal damage to the bone surfaces and adjacent structures. 4,5 The touch screen of the main unit permits selection of the specific insert, and modulation of the irrigation and the power according to the bone density. The device uses low-frequency ultrasonic waves (24.7-29.5 kHz), the applied power can be modulated …
Reoperation and the centrifugal pump?
1992
Postperfusion syndrome is still a problem in long cardiac operations using extracorporeal circulation (ECC). To evaluate whether or not centrifugal blood pumping during open heart surgery is beneficial, a randomized, prospective study was undertaken of 50 consecutive patients undergoing elective coronary artery bypass grafting. The patients were divided into two groups of 25 each. In group 1 a centrifugal pump (Biomedicus) was used as arterial blood pump, while in group 2 a roller pump (Stockert) was used. The two groups did not differ significantly and the number of variables during surgery was kept low (identical perfusion set, two surgeons, minimal cardiotomy suction). The parameters stu…
An automatic system for stepwise treatment of solid samples and application to pollution evaluation by measuring ion lixiviation rates in lichens
1999
An automatic system for the stepwise treatment of solid samples is described. The system is controlled by a PC computer that is connected to a burette equipped with a three-way valve, to a peristaltic pump, and to a robot arm through two serial interfaces. In a cycle, the burette introduces a solvent volume in the sample cell, sonication is applied, and, after a fixed time, the pump carries the solvent to the vial selected by the robot arm. Measurements can be performed both in-line and off-line by analyzing the vial series. The program was written in Visual Basic 3. Lixiviation rates of several cations from the lichen Ramalina farinacea were measured by capillary zone electrophoresis using…
In-vitro assessment of centrifugal pumps for ventricular assist.
1990
Currently two major types of centrifugal pumps are commercially available for ventricular assist: the Biomedicus-cone (Group I) and the Centrimed-impeller pump (now Sarns 3M) (Group II). To compare them for blood trauma and hemolysis, an in-vitro experiment was designed with a Stockert roller pump as a standard control (Group III). The in-vitro circuit was constructed consisting of a pump head, electromagnetic flow probe, polyvinyl chloride tubing and a reservoir, identical for all groups. Human ACD blood was used for priming and was circulated with a flow rate of 2 L/min for 24 h. Blood samples were taken at 0, 1, 3, 6, 12, and 24 h and zero control values were subtracted from the resultin…